Mechanical Plant
\(P_n = \frac{P_0}{100}\left(5 + 47.5\times \frac{BMM_{avg|t:40\rightarrow 80}}{BMM_0} +47.5\times \frac{BML_{avg|t:33\rightarrow 100}}{BML_0}\right) \)
Industrial Electronic Equipment
\(P_n = \frac{P_0}{100}\left(5 + 32\times \frac{BIE_{avg|t:40\rightarrow 80}}{BIE_0} +63\times \frac{BML_{avg|t:33\rightarrow 100}}{BML_0}\right) \)
Rotating Electrical Machinery
\(P_n = \frac{P_0}{100}\left(5 + 40\times \frac{BEE_{avg|t:58\rightarrow 75}}{BEE_0} +55\times \frac{BEL_{avg|t:58\rightarrow 100}}{BEL_0}\right) \)
Distribution Transformers \(<\) 10 MVA
\( P_n = \frac{P_0}{100}\left(5 + 35\times \frac{BEL_{mth:n-1}}{BEL_{mth:0}} + x\times \frac{BLT_{mth:n-2}}{BLT_{mth:0}}+ y\times \frac{{LMEcu}_{date:agreed}}{{LMEcu}_{day:0}}\right) \)
\(x+y=60\)
\(y\) is the proportion of the contract price at the date of tender
wholly related to copper (i.e. the weight of copper multiplied by the cost
per kilo of copper at tender date, expressed as proportion of the contract
price at date of tender. This proportion should be scaled down by \(60\%\) to
preserve the material proportion of the formula.
Distribution Transformers \(\geq\) 10 MVA
\(P_n = \frac{P_0}{100}\left(5 +47.5\times \frac{BEL_{mth:n-1}}{BEL_{mth:0}} + x\times \frac{BLT_{mth:n-2}}{BLT_{mth:0}}+ y\times \frac{{LMEcu}_{date:agreed}}{{LMEcu}_{day:0}} + z\times \frac{{TDEoil}_n}{{TDEoil}_0} \right) \)
\(x+y+z=47.5\)
\(y\) is the proportion of the contract price at the date of tender wholly related to copper (the weight of copper multiplied by the cost per kilo of copper at tender date, expressed as proportion of the contract price at date of tender
\(z\) is the proportion of the contract price at date of tender which is wholly related to insulating oil (i.e. the quantity of insulating oil multiplied by the cost per litre of insulating oil at tender date, expressed as a proportion of the contract price at date of tender
Large Power Transformers
\( P_n = \frac{P_0}{100}\Bigl( 5 +25\times \frac{BEL_{mth:n-1}}{BEL_{mth:0}} + 20\times \frac{BLT_{mth:n-2}}{BLT_0} +10\times \frac{BIS_{mth:n-2}}{BIS_0} + 15\times \frac{LMEcu_{ order|day:1} }{ LMEcu_{ day:0} } + 5\times \frac{ TDEoil_{n-2} }{ TDEoil_{mth:0-1} } + 20\times \frac{TDEgoes_{n-2}}{TDEgoes_{mth:0-1}} \Bigl)\)
Turbo Generating & Allied Plant
\(P_n = \frac{P_0}{100}\left(5 +47.5\times \frac{BEL_{avg|t:33\rightarrow 100}}{BEL_0} + 33.25\times \frac{BIS_{avg|t:40\rightarrow 80}}{BIS_0} + 14.25\times \frac{BMM_{avg|t:40\rightarrow 80}}{BMM_0} \right)\)
Distribution Feeder Pillars
\(P_n = \frac{P_0}{100} \left(5 + 56\times \frac{{BEL}_{mth:n-1}}{{BEL}_{mth:0-1}} + 39\times \frac{{BEE}_{mth:n-1}}{{BEE}_{mth:0-1}} \right)\)
Switchgear \(\leq 36 kV\)
\(P_n = \frac{P_0}{100}\left(5 + 45\times \frac{{BEL}_{mth:n-1}}{{BEL}_{mth:0}} +50\times \frac{{BEE}_{mth:n-1}}{{BEE}_{mth:0-1}}\right)\)
Switchgear \(> 36 kV\)
\( P_n = \frac{P_0}{100}\left(5 + 45\times \frac{{BEL}_{avg|mth:n-3,n-2,n-1}}{{BEL}_{mth:0}} +50\times \frac{{BEE}_{avg|mth:n-4,n-3}}{{BEE}_{mth:0}}\right) \)
Factory Built Assemblies for Control Equipment
\(P_n = \frac{P_0}{100}\left(5 +47.5\times \frac{{BEL}_{mth:n-1}}{{BEL}_{mth:0}} + 47.5\times \frac{BFB_{mth:n-1}}{BFB_{mth:0}} \right) \)
Factory Built Assemblies for Low Voltage Switchgear
\(P_n = \frac{P_0}{100}\left(5 +47.5\times \frac{{BEL}_{mth:n-1}}{{BEL}_{mth:0}} + 47.5\times \frac{BEE_{mth:n-1}}{BEE_{mth:0}} \right)\)
Service and Maintenance (Electrical)
\(P_n = \frac{P_0}{100}\left(5 + x\times \frac{{BEL}_{mth:n-1}}{{BEL}_{mth:0}} +y\times \frac{BEE_{mth:n-1}}{BEE_{mth:0}}\right)\)
\(x + y = 95\)
Service and Maintenance (Mechanical)
\(P_n = \frac{P_0}{100}\left(5 + x\times \frac{{BML}_{mth:n-1}}{{BML}_{mth:0}} +y\times \frac{BMM_{mth:n-1}}{BMM_{mth:0}}\right)\)
\(x + y = 95\)
Electrical / Mechanical - Service
\(P_n = \frac{P_0}{100} \left(5 + 23.75\times \frac{{BEE}_{n-1}}{BEE_{mth:0}} +23.75\times \frac{{BEL}_{mth:n-1}}{{BEL}_{mth:0}} + 23.75\times \frac{BMM_{mth:n-1}}{BMM_{mth:0}} +23.75\times \frac{BML_{mth:n-1}}{BML_{mth:0}}\right)\)
Electrical / Mechanical - Non Service
\(P_n = \frac{P_0}{100} \left(5 + 23.75\times \frac{{BEE}_{avg|t:40\rightarrow 80}}{{BEE}_0} +23.75\times \frac{{BEL}_{avg|t:33\rightarrow 100}}{{BEL}_0} + 23.75\times \frac{BMM_{avg|t:40\rightarrow 80}}{BMM_0} +23.75\times \frac{BML_{avg|t:33\rightarrow 100}}{BML_0}\right)\)